Caltest 300

Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratorium. 

我要諮詢

Analyzer Caltest 300 is used for testing of single and three phase energy meters and current transformers:

  • in accuracy class 0.05 and 0.1,
  • in current range 0.001...3000A, with additional functions:
  • verification of power network wiring,
  • measure, recording and analyze of power network parameters and power quality,
  • multi-variant data entering – digital and graphical display, internal memory, local printing, transmission by interface and analysis on PC computer.

Caltest 300 Portable Analyzer and Tester

  • Measure of power network parameters (class 0.05 or 0.1)
  • Voltage range 0.5…300V and 0.1…40kV
  • Current range 0.001...10(100)(1000)(2000)(30/300/3000)A
  • Testing of energy meters
  • Testing of Current and Potential Transformer
  • Vector and oscilloscope charts of three phase network
  • Recording and analyse of power quality
  • Powering from measurement network
  • Calibration Certificate

Optionally Caltest 300 set may be equipped in:

  • computer Laptop,
  • CT10A miniature electronic compensated clamps up to 10A (3pcs),
  • CT100A miniature electronic compensated clamps up to 100A (3pcs),
  • CT1000A electronic compensated clamps up to 1000A (3pcs),
  • FCT3000A electronic compensated flexible clamps in ranges 30/300/3000A (3pcs),
  • AmpLiteWire 2000A primary current sensors up to 2000A (3pcs),
  • VoltLiteWire 40kV primary voltage sensors up to 40kV (3pcs),
  • AKD300 current cables up to 120A (6pcs) with set (18unit) of replaceable terminals,
  • KAS100 transportation, plastic case for carrying and working with analyzer,
  • C091A T3475-001 plug Amphenol for relay outputs.

Analyzer Caltest 300 is used for testing of single and three phase energy meters and current transformers:

  • in accuracy class 0.05 and 0.1,
  • in current range 0.001...3000A, with additional functions:
  • verification of power network wiring,
  • measure, recording and analyze of power network parameters and power quality,
  • multi-variant data entering – digital and graphical display, internal memory, local printing, transmission by interface and analysis on PC computer.

Caltest 300 Portable Analyzer and Tester

  • Measure of power network parameters (class 0.05 or 0.1)
  • Voltage range 0.5…300V and 0.1…40kV
  • Current range 0.001...10(100)(1000)(2000)(30/300/3000)A
  • Testing of energy meters
  • Testing of Current and Potential Transformer
  • Vector and oscilloscope charts of three phase network
  • Recording and analyse of power quality
  • Powering from measurement network
  • Calibration Certificate

Optionally Caltest 300 set may be equipped in:

  • computer Laptop,
  • CT10A miniature electronic compensated clamps up to 10A (3pcs),
  • CT100A miniature electronic compensated clamps up to 100A (3pcs),
  • CT1000A electronic compensated clamps up to 1000A (3pcs),
  • FCT3000A electronic compensated flexible clamps in ranges 30/300/3000A (3pcs),
  • AmpLiteWire 2000A primary current sensors up to 2000A (3pcs),
  • VoltLiteWire 40kV primary voltage sensors up to 40kV (3pcs),
  • AKD300 current cables up to 120A (6pcs) with set (18unit) of replaceable terminals,
  • KAS100 transportation, plastic case for carrying and working with analyzer,