簡介
KFGS
Listed here are the KFGS series gages with a suitable lead-wire cable for strain measurement of concrete.
我要諮詢Listed here are the KFGS series gages with a suitable lead-wire cable for strain measurement of concrete.
★ 詳細規格請洽詢,我們將有專業人員為您服務!
Contents
When ordering, suffix the lead-wire cable code to the model number with a space in between.
E.g.
KFGS-30-120-C1-11 With a vinyl-coated flat 3-wire cable 1 m long
→ KFGS-30-120-C1-11 L1M3R
Notes on pre-attached lead-wire cables
● Standard color of the 2-wire cable pre-attached to uniaxial gages is red (R).
If desired, allows a white, green, yellow or black cable to be pre-attached.
● Standard 3-wire cable pre-attached to uniaxial gages has red stripes (R).
If desired, allows the red stripes to be changed to blue or yellow stripes.
● In the case of a biaxial gage and triaxial gage, 2-wire cables are color-coded with red, white and green stripes for 0°, 90° and 45°, respectively and 3-wire cables, with red, yellow and blue stripes for 0°, 90° and 45°, respectively.
The letter code is S in common.
Materials Resistive element | CuNi alloy foil |
Materials Base | Polyimide |
Operating temperature in combination with major adhesives after curing (°C) | CC-35: -10 to 80ºC |
Operating temperature in combination with major leadwire cables (°C) | Polyester-coated copper wire: -196 to 150ºC Vinyl-coated flat cable (L-6, L-7): -10 to 80ºC Mid-temperature cable (L-11, L-12): -100 to 150ºC |
Self-temperature-compensation (°C) | 10 to 100ºC |
Applicable linear expansion coefficients (×10-6/℃) | 11 |
Strain limits at normal temp. (approx. %) | 5.0 |
Fatigue lives at normal temp. (times) | 1.2x107 (±1500μm/m) |