產品介紹∣Sulfimax GX online GAS
Search
Sulfimax GX online GAS

簡介

Sulfimax GX online GAS

H2S analyzer for continuous quantitative determination of hydrogen sulphide (H2S) in gas mixtures

我要諮詢

Continuous quantitative determination of hydrogen sulphide (H2S) in gas mixtures

The Sulfimax GX online GAS was developed for the continuous determination of hydrogen sulphide (H2S) in gas mixtures.

The system is designed in such a way that both very high concentrations (100 - 20000 ppm) and low contents in the range of the odour threshold (0.1 - 100 ppm) can be measured by means of a built-in dilution stage.

The Sulfimax GX online GAS contains a selective amperometric sensor with gas selective membranes, membrane pumps for gas transportation and sample transfer and an integrated PC for continuous recording of measurement data, trends and alarm states. The measurement results can be transmitted to the control room via digital (alarm) and analogue outputs.

The Sulfimax GX online GAS enables gas analysis without drift phenomena in oxygen-free gases, such as biogas, due to its automatic purging circuits. Due to the gentle mode of operation, the service life of the sensor is considerably extended.

Due to its mode of operation, the Sulfimax GX online GAS can be used as the basis for H2S-adapted control of enrichment and purification stages.

The device is available in the same way for the monitoring of ammonia (NH3), sulphur dioxide (SO2) or ozone (O3).

Features

  • Continuous H2S gas analysis (measuring time < 5 min)
  • Robust analysis method (drift stability)
  • Simple calibration
  • Simple, clear software
  • Integrated purging steps to ensure a constantly updated sample for analysis
  • Active sample intake of the gas up to a distance of 100 m – variable setup of device (wall mounted)
  • Also available for measuring ammonia (NH3), sulphur dioxide (SO2) or ozone (O3)

Applications

  • Online recording of the current H2S concentration as basis for H2S-adapted controls (e. g. pump sump, gravity lines, collecting tanks)
  • Biogas processes, fermentations
  • Environmental analytics
  • Wastewater analysis
  • Landfill leachate monitoring

Fields of applications

  • Municipal wastewater associations
  • Industrial sectors
  • Biogas plants
  • Petroleum processing

Advantages

  • Fully automated sample dosing
  • Hardly any cross-sensitivities due to selective electrochemical sensor
  • Output 4 - 20 mA for integration of the H2S signal into the local control system
  • Long sensor life due to intermittent gas path gas path switching
  • Integrated rinsing steps for measuring of continually fresh samples
  • Active sample aspiration, thus free installation (wall mounting) with up to 100 m distance from the sampling point
Measuring points Max.2
Sampling By suction via a transfer line (up to 100 m)
Sample volume 0.1 - 100 mL (depending on application)
Sample pressure Ambient or pressurized
Typical measuring time < 5 min (depending on sample)
Measuring range 0.1 ppm - 20000 ppm (2 %)
Gas supply Internal pump or pressure controller
Alarm Dry contact
Signal output 4 - 20 mA
Power supply 220 - 230 V, 50 Hz, 2 A
Power input 100 W
Protection type IP 66
Dimensions 660 x 250 x 400 mm (W x D x H)
Weight 9 kg