產品介紹∣Fermentation test system GärOnA
Search
Fermentation test system GärOnA

簡介

Automated lab fermentation system with online gas analysis

我要諮詢

Anaerobic lab fermentation test system with integrated gas analysis

Meaningful fermentation tests are necessary for an efficient biogas manufacturing. With the test results, you can describe the microbiological processes and the degradation characteristics of new substrates. The procedures for fermentation tests are specified, among others, in the VDI guideline 4630.

Now, the batch and continuous fermentation tests can be carried out fully automatically with the system GärOnA.

The pressure range in the fermentation vessels can be minimized. This has a positive effect on the solubility equilibrium of methane, carbondioxide and other gas components in the liquid phase.

While the depressurization a biogas sample from a vessel is fed automatically to the gas chromatograph where it is analysed. It is possible to record the change of the methane formation or the time course of the methane formation rate.

The fully automated lab fermentation system GärOnA allows very easy and exactly the investigation of anaerobic digestion process, combined with a wide information content.

Advantages

  • Compact and portable lab analyzer
  • Fully automated and controlled fermentation vessels
  • Pressure measurement for determination of formed biogas quantity
  • On a roll-off magnetic stirrer 15 measuring stations und 1 measuring cell as a reference
  • Controlled depressurization via valve manifolds
  • Determination of different gas components with integrated gas chromatograph (CO2, CH4, trace gases)
  • Waterless incubation by an incubator unit
  • Compensation of temperature and air pressure changes for accurate data evaluation
  • 2000 programmable runs on the Online-GC
Fermentation test system  
Measuring stations: 15 + 1 measuring cell as a reference
Fermentation vessels: Laboratory bottles of DURAN® glass,
500 mL, with GL 25 or GL 45
Measuring range: ± 100 mBar
Temperature measurement: Caps with integrated pressure sensor
Pressure control: Automatic depressurization via 3 valve manifolds
Incubator  
Outer dimensions: 835 x 650 x 1025 mm (W x D x H)
Inner dimensions: 600 x 400 x 480 mm (B x T x H) (W x D x H)
(115 Liter incubation chamber)
Weight: 150 kg (with internal installations)
Power supply: 230 V/50 Hz, 460 W
Permissible incubation temperature: 4 ... 65 °C
Online gas chromatograph  
Version: Mobile gas analyzer "MobilGC", 19"
with thermal conductivity detector
and up to 2 columns
Column temperature: 150 °C (up to 300 °C selectable temperature
programs)
Transfer line: Heated up to 60 °C
Sample loop: 200 µL (10 ... 1000 µL selectable)
Carrier gas: Argon (selectable depending on the detector)
Measuring range:
CO2
CH4
H2
Depending on the configuration
0 ... 100 Vol.-%
0 ... 100 Vol.-%
0 ... 5 Vol.-%
Detection limits:
CO2
CH4
H2
Depending on the configuration
0,1 Vol.-% (1000 µL loop)
0,1 Vol.-% (1000 µL loop)
50 ppm (1000 µL loop)
Dimensions: 560 x 450 x 220 mm (W x D x H)
Weight: 25 kg