簡介
NEC-WN-FOUR-B-4HS
The WaveNeuro Four Multichannel Fast Scan Cyclic Voltammetry (FSCV) Potentiostat System Plus Bundle with 4-Channel Headstage Kit is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers. We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you. Designed by FSCV scientists for FSCV scientists, the WaveNeuro Four is well-designed, of high quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher. The WaveNeuro Four seeks to fill the gap that exists for commercial fast-scan cyclic voltammetry (FSCV) systems. The system provides you with the following:
The WaveNeuro Four Fast Scan Cyclic Voltammetry (FSCV) Potentiostat Basic Bundle with Four Channel Headstage is a unique electrochemical instrument you will not find from other traditional electrochemical suppliers. We are excited to bring high quality, regularly available, and uniquely designed neuroelectrochemical research products to you. Designed by FSCV scientists for FSCV scientists, the WaveNeuro Four is well-designed, of high-quality construction, and supported by a company dedicated to supporting the instrument, as well as you the researcher. The WaveNeuro Four seeks to fill the gap that exists for commercial multichannel fast-scan cyclic voltammetry (FSCV) systems.
The WaveNeuro Four Multichannel Potentiostat was designed for the scientist (neuroscientist, psychologist, physician, chemist, biologist, etc.) who seeks to study the link between the brain chemistry of electroactive species (such as monoamines, catecholamines like dopamine and serotonin, oxygen, peroxide, etc.) and physiology (such as structure, function, disease, neural transmission, etc.) and behavior (such as addiction, impulsivity, decision-making, etc.). Microdialysis, still a technique used in the field, can provide high spatial resolution for the detection of these chemical species but offers poor temporal resolution. FSCV, as a technique, provides both high spatial and high temporal resolution. Coupled with carbon fiber microelectrodes, FSCV provides a well-established platform for in-vivo and in-vitro experimentation.
The WaveNeuro Four has been developed in response to more of the FSCV community who want to make simultaneous measurements. The WaveNeuro Four is like the WaveNeuro One, however it can be used to apply up to four independent waveforms, simultaneously. Perhaps you want to measure dopamine in several locations during a single experiment? Perhaps you want to increase throughput and collect FSCV data in four different animals/tissues simultaneously? With the WaveNeuro Four, we have made it possible – without having to custom order such a system for $30,000 and have to wait 8 – 12 months for delivery! The WaveNeuro Four uses a single PCIe-6363 (like all WaveNeuro FSCV potentiostats) and is compatible with HDCV software.
Traditionally, the products and instrumentation required to perform FSCV have only been available through scientific connections with developing laboratories. As the technique has grown in popularity, due in part to its relative ease of use, the availability of instrumentation has not followed the same trend. We are excited to bring such FSCV instrumentation to the market, thereby providing the robust technical, service, and sales support you have come to expect in the field of research instrumentation.
The WaveNeuro Four seeks to fill the gap that exists for commercial FSCV systems by providing systems with many novel features, such as:
Potentiostat Bundle | |||
[NEC-WN-FOUR-B-4HS] |
WaveNeuro Four Basic Bundle with Four-Channel Headstage Kit |
||
WaveNeuro Four Basic Bundle with 4-Channel Headstage | |||
AF01FSCV4 |
WaveNeuro Four Mutltichannel Potentiostat System power cord sold separately |
||
AB01DUM1-LF |
Dummy Cell for WaveNow Potentiostat bundle contains two |
||
AB01HC0701 |
Four Channel Headstage Adapter for WaveNeuro Four |
||
AC01HS4 |
Four Channel FSCV Headstage Amplifier NOTE: A working electrode driven systems means the waveform is applied to the working electrode, which is then later software subtracted. Such a design is consistent with the general FSCV research community. |
||
AC01HC0503 |
Four Channel Headstage-to-Microelectrode Coupler Wire Assembly |
||
RRHC0620 |
Four-Channel Headstage Cable |