簡介
CTG-A-3ES-18
這是三電極電池測試單元和其它redox.me電池測試單元所附的標準電池盒。當研究人員想在三電極設置中對電池和超級電容器材料進行可重複的電化學量測時,它是理想的選擇。電池盒可以在電池基座之間交換。因此,若擁有多個電池盒,可在另一個電池盒處於清潔狀態時可使用另一個電池盒,讓您的實驗測試不會中斷。
我要諮詢選擇電解液類型:
選擇電極直徑:
介紹
這是三電極電池測試單元和其它redox.me電池測試單元所附的標準電池盒。當研究人員想在三電極設置中對電池和超級電容器材料進行可重複的電化學量測時,它是理想的選擇。電池盒可以在電池基座之間交換。因此,若擁有多個電池盒,可在另一個電池盒處於清潔狀態時可使用另一個電池盒,讓您的實驗測試不會中斷。
應用說明
該電池可用於所有常見的電池測量,如恒電流循環、循環伏安法或電化學阻抗頻譜。液體和固態或凝膠聚合物的電解質都可以被研究。此外,還可以研究超級電容器材料的特性和性能。可以檢查各種材料,包括典型的鋰離子電極(石墨、NMC、LTO等)和其它化學材料 ——鈉、鎂、鉀…。它還可以應用於測量隔板和電解質的離子電導率。
規格
產品包括
Select electrolyte type:
Select elelctrode diameter:
This is default cartridge included in Three Electrode Battery Test Cell and other redox.me battery test cells. It is ideal choice when researcher wants to perform reproducible electrochemical measurements of battery and supercapacitor materials under controlled compression in a three-electrode setup. The battery cartridges are exchangeable between cell bases, therefore it is convenient to have multiple cartridges and use one while the other is in cleaning etc.
The Battery Cartridge – Three Electrode Setup consists of upper and lower electrode plungers, separator lock ring and reference electrode punch. The (default) electrode plungers are designed for planar electrodes with diameter of 18 mm and total sandwich thickness up to 2.5 mm. The diameter of separator shall be at least 2 mm larger than electrode diameter (max. 22 mm). The lock ring secures the separator in the electrode cartridge allowing easy and safe electrodes insertion, while ensuring accurate alignment. The upper and lower electrode plungers are available in various materials: 316L/317L Stainless Steel (default), copper, aluminum, nickel, gold plated nickel, etc. The punch-type reference electrode is installed from the side of the electrode cartridge. Thanks to sharp edged hole at the end of the pin the reference electrode (Li/Na/K etc.) can be easily punched from the metal foil and directly loaded into cell. The magnetic mount facilitates rapid assembly of the cartridge in the cell base For 2-electrode measurements the reference electrode feedthrough hole can be closed with the reference electrode punch.
The battery cartridge elements are constructed with materials that are inert to the sample (Stainless steel 316L/317L and PEEK). It well fits aqueous (FKM and EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. Good electrical contact is ensured by gold plated pins. The battery cartridge can be effortlessly installed in the Three Electrode Battery Test Cell even when operating in the glove box, reducing possible human error to minimum.
Application note
This cell can be used for all common battery measurements, such as galvanostatic cycling, cyclic voltammetry or electrochemical impedance spectroscopy. Both liquid and solid-state electrolytes can be studied. Additionally, properties and performance of supercapacitor materials can be investigated. Various materials can be examined, including typical Li-ion electrodes (graphite, NMC, LTO, etc.) and other chemistries – sodium, magnesium, potassium etc. It can also be applied to measure the ionic conductivity of separators and electrolytes.
Specification
Product includes