簡介
ECD-4-nano
Advanced Electrochemical Dilatometer for the measurement of electrode expansion with nanometer resolution.
Advanced test cell for the measurement of the electrode expansion in the nanometer range.
The ECD-4-nano takes dilatometry measurements to the next level
The ECD-4-nano is a high-resolution electrochemical dilatometer. The most powerful version offers a capacitive parallel plate sensor system with a resolution of better than 5 nanometers. This makes the ECD-4-nano the perfect instrument for detecting thickness changes of the individual electrode or the full cell stack during the electrochemical cycle.
The ECD-4-nano‘s completely redesigned test cell features a corrosion-resistant cell bottom and a new One-Seal concept that significantly improves tightness over previous ECD-3 models. This enables stable long-term operation as well as the use of a wide range of electrolytes.
To further improve workflow and handling, we have now integrated the ECD-4-nano into the PAT system. The dilatometer can be inserted directly into a PAT-Tester-x or a docking station such as the PAT-Clamp-1. This allows a space-saving and fast setup of the instrument. Needless to say, the integrated PAT-Button also ensures automatic recognition of the test cell in our EL-Software measurement software.
Sample Test Results
Sample Setup
Sample Setup
Working principle of the ECD-4-nano (3-electrode setup)
he working electrode (WE) and the counter electrode (CE) are separated by a stiff glass frit soaked with electrolyte. The upper WE is sealed by means of a flexible metal membrane, through which any charge-induced thickness change is transmitted towards the sensor/load unit attached on top. The fixation of the glass frit ensures that only the thickness change of the working electrode is being detected without interference from the CE.
Length | 64 mm | |
Width | 67 mm | |
Height | 149 mm | |
Weight | 2 kg | |
Sample diameter | 10 mm | |
Glass T-Frit (Separator) | 12.5/10 x 3.5 mm | |
Separator diameter (full cell mode) | max. 10 mm | |
Working (upper) electrode diameter | max. 10 mm | |
Counter (lower) electrode diameter | max. 12 mm | |
Gas pressure sensor: | 0 to 3 bar abs. | |
Chemical compatibility | Aprotic organic electrolytes | |
Cell electrolyte volume | approx. 0.2 ml | |
Operational temperature range (cell and sensor) | -20 to 80° C | |
Operational temperature range (conditioning electronics and data logger) | 0 to 40 °C | |
Load on test specimen | approx. 1 Newton | |
Product variants | ECD-4-nano | ECD-4 |
Displacement sensor type: | Capacitive | LVDT |
Displacement range: | 250 μm | 500 μm |
Displacement resolution: | ≤ 5 nm | ≤ 50 nm |
Compatible PAT docking stations and potentiostats