產品介紹∣磁性安裝光纖光譜電化學液流電池 - MM SPECTRO-EFC,SMA 905,1.75 ML
Search

磁性安裝光纖光譜電化學液流電池 - MM SPECTRO-EFC,SMA 905,1.75 ML
MM SPECTRO-EFC, SMA 905, 1.75 ML - MAGNETIC MOUNT OPTICAL FIBER SPECTRO-ELECTROCHEMICAL FLOW CELL

【Redox.me】電化學周邊耗材 光譜電化學電池

磁性安裝光纖光譜電化學液流電池 - MM SPECTRO-EFC,SMA 905,1.75 ML

簡介

C-A-MM_SPEC_EFC-1.75-SMA, C-O-MM_SPEC_EFC-1.75-SMA

This is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra. Applied collimating lenses are curved optical lenses that enable parallel irradiation of the sample. Each lens is 5 mm in diameter, has a focal length of 10 mm and wavelength range of 185-2500 nm.

我要諮詢

This is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra. Applied collimating lenses are curved optical lenses that enable parallel irradiation of the sample. Each lens is 5 mm in diameter, has a focal length of 10 mm and wavelength range of 185-2500 nm. The cell consists of a polyether ether ketone (PEEK) flow chamber equipped with a magnetic mount sample holder (a screw version is available on request), a screw mount quartz window holder and two different mini tripods. It well fits aqueous (FKM/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The cell is meant to be used with a standard reference electrode having 6 mm in diameter and a counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.

Application note
Spectroelectrochemical cell is used to study the relation between absorbance/transmittance and electrochemical potential. It enables real-time monitoring of optical change in electrochromic materials. It also enables in-situ spectral acquisition for detection, identification and characterization of short-lived electrochemically-generated species/intermediates, resulting in a detailed investigation of the mechanistic pathways of redox processes.

Operating Video Manual

Select electrolyte type:
water-based electrolyte
organic solvent

Specification
nominal aperture area: 1 cm2 (other values on request)
optical path length (electrolyte thickness): 12 mm
flow chamber volume: 1.75 mL
maximum substrate thickness: 4 mm
electrode plug diameter: 6 mm
minimum substrate size: 17 mm x 25 mm
recommended substrate size: 25 mm x 25 mm
fiber connector: SMA 905, 6.35 mm ferrule
irradiated spot size: 5 mm in diameter, 19.6 mm2 area.

Intrastat data
HS Code: 90275000
Country of Origin: Sweden
NET weight: 200g

Product includes
1 x sample mount – 0046CPEMAMM
1 x flow chamber – 0044CPEMAMM
1 x quartz window - 0045PQGMA
1 x window/fiber holder - 0047PSSMA
2 x collimating lanes with SMA 905 optical fiber connector – 0048PHYCM
1 x set of screws – 0032PNYCM
1 x plug – 0005CPEMA
1 x Manfrotto PIXI table tripod – 0028PHYCM
1 x XS Bendy Flexible Tripod - 0043PHYCM