專門對合成和生物燃料生產線常見的四種原子進行可靠、準確的分析。
在這個強大且不斷發展的全球產業結構中,與合成燃料或生物燃料生產的相關行業扮演著重要的角色。對於這類的衍生產品,BWB Technologies 提供了一種混合火焰光度計,我們將其命名為 Syn Fuels。
BWB SYN FUELS 火焰光度計是第一款也是唯一一款能夠同時偵測並顯示所有 4 種元素的 4 通道火焰光度計。BWB SYN FUELS 是一款高品質、高性能的儀器,採用現代技術來提高準確性和穩定性,同時顯著縮短分析時間。
BWB SYN FUELS 火焰光度計的流體處理部分,採用了專有的工程熱塑性塑料,這些熱塑性塑料具有高度耐化學性,可承受合成燃料生產設施中使用的溶劑。
我們在全球的客戶經過統計,大多數是甜菜或甘蔗精煉廠購買 BWB Sugar ,而生物轉化工廠則購買 Syn Fuels FES。
產品特點:
Sample rate 2 – 3.5ml/min
Tubing materials PTFE and Teflon
Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D)* For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size Syn Fuels Flame Photometer
Shipping
Weight Syn Fuels Flame Photometer – 14kg (30.8lbs) Shipping – 25kg (55.1lbs)
Power requirements 100V – 250V AC at 50 or 60Hz
Readout LCD, four line, alpha numeric, back lit. |
Optimal range Single point calibration Na 0.1 – 60ppm K 0.05 – 100ppm Li 0.05 – 50ppm Ca 1.0 – 100ppm
Multi Point Calibration Na 0.1 – 1000ppm K 0.05 – 1000ppm Li 0.05 – 1000ppm Ca 1.0 – 1000ppm
Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).
Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm
Limit of detection (LOD) and limit of quantification (LOQ) displayed LOD LOQ Na – 0.03ppm Na – 0.1ppm K – 0.02ppm K – 0.05ppm Li – 0.02ppm Li – 0.05ppm Ca – 0.3ppm Ca – 1ppm |
Time to stability Less than 15 seconds after sample is introduced into the flame
Ions measured Simultaneous measurement of Na, K, Li, Ca
Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .CSV and .PDF generated reports and files via FP-PC software Collection Cup fitted as standard allowing live reading
Recommended minimum warm uptime based on ambient temperature 21°C – 25 minutes
Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min *with modifications. BWB Technologies recommends either Propane or Butane for optimum results. |
Sample rate 2 – 3.5ml/min
Tubing materials PTFE and Teflon
Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D)* For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size Syn Fuels Flame Photometer
Shipping
Weight Syn Fuels Flame Photometer – 14kg (30.8lbs) Shipping – 25kg (55.1lbs)
Power requirements 100V – 250V AC at 50 or 60Hz
Readout LCD, four line, alpha numeric, back lit. |
Optimal range Single point calibration Na 0.1 – 60ppm K 0.05 – 100ppm Li 0.05 – 50ppm Ca 1.0 – 100ppm
Multi Point Calibration Na 0.1 – 1000ppm K 0.05 – 1000ppm Li 0.05 – 1000ppm Ca 1.0 – 1000ppm
Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).
Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm
Limit of detection (LOD) and limit of quantification (LOQ) displayed LOD LOQ Na – 0.03ppm Na – 0.1ppm K – 0.02ppm K – 0.05ppm Li – 0.02ppm Li – 0.05ppm Ca – 0.3ppm Ca – 1ppm |
Time to stability Less than 15 seconds after sample is introduced into the flame
Ions measured Simultaneous measurement of Na, K, Li, Ca
Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .CSV and .PDF generated reports and files via FP-PC software Collection Cup fitted as standard allowing live reading
Recommended minimum warm uptime based on ambient temperature 21°C – 25 minutes
Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min *with modifications. BWB Technologies recommends either Propane or Butane for optimum results. |