產品介紹∣交流阻抗架構
Search
交流阻抗架構

簡介

ProboStat™ ACIS is a sample holder dedicated for AC conductivity measurements and 2-electrode impedance spectroscopy on small disk samples at high temperatures and under controlled atmospheres.

Special design of the hot-zone parts facilitates mounting and replacement of test samples compared with the standard ProboStat™ furnishment.

The test sample rests in a support tube, is contacted by electrode connects, and held stably in place with a spring load assembly. The setup is assembled in a single chamber mode and can be fed with virtually any gas. The sample holder is designed to operate at near-atmospheric pressure, but can be pumped to low vacuum, or hold up to 15 bar. Electrical connections are made via standard coax cables.

我要諮詢

The system is supplied with a standard ProboStat™ base unit and can be expanded for any sample geometries and measurements that ProboStat™ can support.

The ProboStat™ ACIS works well with all instrumentation such as impedance spectrometers, LCR meters and potentiostats from Solartron, PAR, Novocontrol, Autolab, Gamry, HP/Agilent, etc.

Temperature range:

  • RT - 1600 °C

Atmospheres:

  • Oxidizing, inert, reducing
  • Wet, dry
  • Corrosive optional
  • 0.01 mbar - 1 bar (15 bar optional)

Base unit:

  • 6 BNC electrode connections
  • 3 thermocouple connections 
  • 4 Swagelok quick-connects - two gas in and two gas out
  • 16 mini-contacts for detachable electrode contacts and thermocouples
  • 3 switches for grounding and shielding options
  • Cooling/heating water hose fittings

Hot zone parts:

  • Specially designed sample support tube of alumina
  • Spring-load assembly of alumina
  • 2 electrode contacts: Pt+alumina
  • Thermocouple: type S or K

Test sample size:

  • Disk diameter: max 15 mm
  • Height: max 10 mm

Outer system dimentions:

  • Enclosing tube diameter: 40 mm
  • Overall length: 75 cm

Materials properties measured and applicable methods:

  • AC conductivity vs T, pO2, pH2O, etc.
  • Impedance spectroscopy
  • Bulk, grain boundary and electrode impedance
  • H/D isotope effect
  • Fuel cell components test
  • Dielectric properties

The system is supplied with a standard ProboStat™ base unit and can be expanded for any sample geometries and measurements that ProboStat™ can support.

The ProboStat™ ACIS works well with all instrumentation such as impedance spectrometers, LCR meters and potentiostats from Solartron, PAR, Novocontrol, Autolab, Gamry, HP/Agilent, etc.

Temperature range:

  • RT - 1600 °C

Atmospheres:

  • Oxidizing, inert, reducing
  • Wet, dry
  • Corrosive optional
  • 0.01 mbar - 1 bar (15 bar optional)

Base unit:

  • 6 BNC electrode connections
  • 3 thermocouple connections 
  • 4 Swagelok quick-connects - two gas in and two gas out
  • 16 mini-contacts for detachable electrode contacts and thermocouples
  • 3 switches for grounding and shielding options
  • Cooling/heating water hose fittings

Hot zone parts:

  • Specially designed sample support tube of alumina
  • Spring-load assembly of alumina
  • 2 electrode contacts: Pt+alumina
  • Thermocouple: type S or K

Test sample size:

  • Disk diameter: max 15 mm
  • Height: max 10 mm

Outer system dimentions:

  • Enclosing tube diameter: 40 mm
  • Overall length: 75 cm

Materials properties measured and applicable methods:

  • AC conductivity vs T, pO2, pH2O, etc.
  • Impedance spectroscopy
  • Bulk, grain boundary and electrode impedance
  • H/D isotope effect
  • Fuel cell components test
  • Dielectric properties