A4300 VA3 Pro是我們用於振動診斷的便攜式設備系列的最新成員。有2個信號輸入和1個測速/觸發輸入。
輸入2提供與三軸傳感器輸入的連接,因此可以同時測量所有3個頻道。
Adash開發的專家系統可以自動檢測機器故障,如- 不平衡、錯位、 鬆動、軸承故障。
同時配置一個非接觸式紅外溫度感測器,可即時測量軸承溫度以及一個LED頻閃儀/手電筒。
A4300 VA3 Pro專為單手操作而設計。該裝置重量僅為780g,電池壽命超過10小時,適合長時間路徑測量。
A4300 VA3 Pro儀器可根據您的要求進行配置選擇可選功能:包含分析、路徑、動平衡、啟動分析或超音波。
選購功能也可另外購買並下載到儀器中開通使用,無需將其送回工廠升級。
訪問Adash官網,查看更多可靠性設備。
主要特點 :
----------------------------------------------------------------------------------------------------------------------------------------------------------------- 振動表 - 標準功能! -----------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
|
Input channels |
3 x AC, ICP® power supply on/off |
Input range |
AC +/- 12 V peak-peak |
AD conversion |
24 bit, 64 bit internal signal processing |
Dynamic range S/N |
120 dB |
Frequency ranges (-3 dB) |
Maximum range: 0.5 Hz - 25 kHz (64 kHz sampling) |
Sampling mode |
Fully simultaneous for all 3 channels |
FFT resolution |
Min. 25 lines |
Measurement modes |
Analyzer - analytical measurements |
Software |
Free version of DDS software (limited database size) |
Data processing |
Real time FFT |
IR temperature measurement |
From -70˚C to +380˚C (-94˚F to +716˚F) |
Trigger |
Manual, External, Amplitude, Tacho |
Display |
Colour 240 x 320 pixels, TFT |
Interface |
USB 2.0, 3.0 compatible |
Operating temperature range |
-10˚C to +50˚C |
Power |
Battery pack for more than 10 hours of continous operation |
Case |
Aluminium - heavy duty |
Weight |
780 g |
Dimensions |
230 x 82 x 32 mm |
The A4300 VA3 Pro is the newest addition to our range of portable devices for vibration diagnostics.
There are 2 signal inputs and 1 tacho/trigger input. Input 2 offers connectivity to a triaxial sensor, therefore all 3 channels can be measured simultaneously. The expert system developed by Adash can automatically detect machine faults susuch as unbalance, looseness, misalignment and bearing faults.
There is a non-contact IR temperature sensor (for immediate bearing temperature measurement) and a LED stroboscope/torch. The A4300 VA3 Pro is designed for one-handed operation. With a weight of just 780g and a battery life of more than 10 hours of operation, the unit is suitable for long route measurements. The A4300 VA3 Pro instrument can be configured according to your requirements by choosing optional modules: analyzer, route, balancer, recorder, run up or ultrasound. Optional mmoo dules can be purchased also additionally and downloaded to the instrument without the need of sending it back to the factory.
Please see more at www.adash.com and come back to us for further assistance with your purchase.
Features
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------ Recorder ----------------------------------------------------------------------------------------------------------------------------------------------------------------- Run up -----------------------------------------------------------------------------------------------------------------------------------------------------------------
|
Input channels |
3 x AC, ICP® power supply on/off |
Input range |
AC +/- 12 V peak-peak |
AD conversion |
24 bit, 64 bit internal signal processing |
Dynamic range S/N |
120 dB |
Frequency ranges (-3 dB) |
Maximum range: 0.5 Hz - 25 kHz (64 kHz sampling) |
Sampling mode |
Fully simultaneous for all 3 channels |
FFT resolution |
Min. 25 lines |
Measurement modes |
Analyzer - analytical measurements |
Software |
Free version of DDS software (limited database size) |
Data processing |
Real time FFT |
IR temperature measurement |
From -70˚C to +380˚C (-94˚F to +716˚F) |
Trigger |
Manual, External, Amplitude, Tacho |
Display |
Colour 240 x 320 pixels, TFT |
Interface |
USB 2.0, 3.0 compatible |
Operating temperature range |
-10˚C to +50˚C |
Power |
Battery pack for more than 10 hours of continous operation |
Case |
Aluminium - heavy duty |
Weight |
780 g |
Dimensions |
230 x 82 x 32 mm |