C-A-PECF_HC-2x1.5-1, : C-O-PECF_HC-2x1.5-1
This is a horizontally mounted, double compartment Photo-Electrochemical Flow H-Cell used to simultaneously investigate thin film photo-anode and photo-cathode. The cell elements are made of PEEK. It well fits aqueous (EPDM/FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is liquid-tight having two separate chambers, each equipped with electrolyte inlet and outlet.
MOREC-A-PTFE_PECF_HC-2x1.5-1, C-O-PTFE_PECF_HC-2x1.5-1
This cell is a sister version of PECF H-Cell 2x1.5 mL. In this cell concept, all elements that stay in contact with an electrolyte or its fumes are made of PTFE and other fluorinated materials (tubing, fittings, and O-Rings).
MOREC-A-MM_FC_PEC_HC-2x15, C-O-MM_FC_PEC_HC-2x15
This is a horizontally mounted, double compartment photo-electrochemical H-Cell used to simultaneously or individually investigate thin film photo-anode and photo-cathode. The cell elements are made of PEEK and Fluoropolymers. It well fits aqueous (FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.
MOREC-A-MM_PEC_HC-2x15-1, C-O-MM_PEC_HC-2x15-1
This is a horizontally mounted, double compartment photo-electrochemical H-Cell used to simultaneously investigate thin film photo-anodes and cathodes. The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having two separate chambers, each equipped with gas inlet and outlet.
MOREC-A-PEC_HC-2x15-1, C-O-PEC_HC-2x15-1
This is a horizontally mounted, double compartment, screw mount photo-electrochemical H-Cell used to simultaneously investigate thin film photo-anodes and (photo)cathodes. The cell elements are made of PEEK. It well fits aqueous (EPDM/FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.
MOREC-A-MM_FC_PEC_SS-15-.2, C-O-MM_FC_PEC_SS-15-.2
This is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically FTO coated or uncoated borosilicate or fused quartz glass).
MOREC-A-HCA_FC_PEC_SS-15, C-O-HCA_FC_PEC_SS-15
This is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically FTO coated or uncoated borosilicate or fused quartz glass).
MOREC-A-MM_PEC_SS-15-1, C-O-MM_PEC_SS-15-1
This is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).
MOREC-A-PEC_SS-15-1, C-O-PEC_SS-15-1
This is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).
MOREC-A-MUL_PEC_SS-15-1, CoA-MUL_PEC_SS-15-1
This is a horizontally mounted, single compartment multiport photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).
MORE