產品介紹∣多功能校正器
Search
多功能校正器

簡介

C101

Series of small dimensions calibrators of AC and DC voltage and current up to 1100V and 100A, with high load possibility.
It allows checking of economical multimeters and clamps meter

我要諮詢
  • Voltage source up to 1100V
  • Current source up to 20A
  • Small dimensions and light weight - 16kg
  • High output power
  • Option C101FC with 100A AC subrange
  • Output power 40VA for 20A AC/DC
  • Software Calpro 101
  • Interface RS232C
  • Calibration Certificate

The C101F Calibrator enables generating of:

  • direct (DC) and alternating (AC) voltages up to 1100V in five subranges 0.1-1-10-100- 1000V,
  • DC and AC currents up to 20.5A in five subranges 0.001-0.01-0.1-1-10A (the C101FC option up to 100A AC).

Frequency of alternating signals may be chosen from values 50Hz (synchronized with power supply frequency), 60Hz, 400Hz or can be programmed in range 45.00...2000Hz. Output signal can be set by means of external keyboard or by standard interface RS232C from PC computer.
The C101F Calibrator is characterised by high accuracy, high output power, small dimensions and light weight.

Technical parameters of C101F Calibrator

Parameter

Range

100mV

1V

10V

100V

1000V

1mA

10mA

100mA

1A

10A

Resolution

100nV

1mV

10mV

100mV

1mV

1nA

10nA

100nA

1mA

10mA

Settings range

1...
205mV

0.01...
2.05V

0.1...
20.5V

1...
205V

10...
1100V

0.01...
2.05mA

0.1...
20.5mA

1...
205mA

0.01...
1.1A

0.1...
20.5A

Uncertainty *)     DC [% of set value+

0.03
+0.005

0.02
+0.002

0.02
+0.003

0.03
+0.003

% setting range]

AC

0.05
+0.005+50mV

0.05
+0.005+0.5mA

0.05
+0.005

Maximum load

20mA

1100mA

200mA

30mA

11V

2V@20A
4V@10A

Frequency

DC; 50Hz synchronized with power supply; 60±0.01Hz and 400±0.1Hz 45.00...99.99±0.01Hz,    100.0...999.9±0,1Hz,    1000...2000±1Hz

Temperature coefficient

±0.1 of uncertainty value / 1°C
in environment temperature +5...+18°C and +28...+40°C

Weight and dimensions

16kg  and  478 (width)x194 (height)x342 (depth) mm

Power supply

230V ±10% / 45…65Hz / 200VA

DC – direct voltage and current, AC – alternating voltage and current
*) Absolute Uncertainty with 95% Confidence Level includes the traceability to external standards,12th months stability, influences of ambient temperature, power supply voltage and load regulation in reference conditions and nonlinearity. For frequency band above 500Hz-linear rise up to double value for frequency 2kHz, typically.

  • Voltage source up to 1100V
  • Current source up to 20A
  • Small dimensions and light weight - 16kg
  • High output power
  • Option C101FC with 100A AC subrange
  • Output power 40VA for 20A AC/DC
  • Software Calpro 101
  • Interface RS232C
  • Calibration Certificate

The C101F Calibrator enables generating of:

  • direct (DC) and alternating (AC) voltages up to 1100V in five subranges 0.1-1-10-100- 1000V,
  • DC and AC currents up to 20.5A in five subranges 0.001-0.01-0.1-1-10A (the C101FC option up to 100A AC).

Frequency of alternating signals may be chosen from values 50Hz (synchronized with power supply frequency), 60Hz, 400Hz or can be programmed in range 45.00...2000Hz. Output signal can be set by means of external keyboard or by standard interface RS232C from PC computer.
The C101F Calibrator is characterised by high accuracy, high output power, small dimensions and light weight.

Technical parameters of C101F Calibrator

Parameter

Range

100mV

1V

10V

100V

1000V

1mA

10mA

100mA

1A

10A

Resolution

100nV

1mV

10mV

100mV

1mV

1nA

10nA

100nA

1mA

10mA

Settings range

1...
205mV

0.01...
2.05V

0.1...
20.5V

1...
205V

10...
1100V

0.01...
2.05mA

0.1...
20.5mA

1...
205mA

0.01...
1.1A

0.1...
20.5A

Uncertainty *)     DC [% of set value+

0.03
+0.005

0.02
+0.002

0.02
+0.003

0.03
+0.003

% setting range]

AC

0.05
+0.005+50mV

0.05
+0.005+0.5mA

0.05
+0.005

Maximum load

20mA

1100mA

200mA

30mA

11V

2V@20A
4V@10A

Frequency

DC; 50Hz synchronized with power supply; 60±0.01Hz and 400±0.1Hz 45.00...99.99±0.01Hz,    100.0...999.9±0,1Hz,    1000...2000±1Hz

Temperature coefficient

±0.1 of uncertainty value / 1°C
in environment temperature +5...+18°C and +28...+40°C

Weight and dimensions

16kg  and  478 (width)x194 (height)x342 (depth) mm

Power supply

230V ±10% / 45…65Hz / 200VA

DC – direct voltage and current, AC – alternating voltage and current
*) Absolute Uncertainty with 95% Confidence Level includes the traceability to external standards,12th months stability, influences of ambient temperature, power supply voltage and load regulation in reference conditions and nonlinearity. For frequency band above 500Hz-linear rise up to double value for frequency 2kHz, typically.